USAutomatic Patriot I Průvodce řešením problémů

Procházejte online nebo si stáhněte Průvodce řešením problémů pro Zahradní nářadí USAutomatic Patriot I. USAutomatic Patriot I Troubleshooting guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 37
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
PATRIOT
High Quality Low Voltage
Vehicular Swing Gate Operator
Solar or AC Charged
PATRIOT I Single Swing Gate Operator
PATRIOT II Dual Swing Gate Operator
Installation/Owners Manual
PROUDLY MADE IN THE USA
www.usautomatic.com
USAutomatic
Zobrazit stránku 0
1 2 3 4 5 6 ... 36 37

Shrnutí obsahu

Strany 1 - PATRIOT

PATRIOT High Quality Low Voltage Vehicular Swing Gate Operator Solar or AC Charged PATRIOT I Single Swing Gate Operator PATRIOT II

Strany 2

8STEP 1 Prepare Actuator for Installation Assemble the actuator to the gate bracket as shown in figure 3A STEP

Strany 3 - Cautions - Very Important

9STEP 3 Mounting of Gate Bracket (PULL to Open Only) Clamp the gate bracket to the gate at the previously determined point and weld to gate. Be sure

Strany 4 - Table Of Contents

10PATRIOT I Single Gate Wiring (only if required) PATRIOT II Dual Gate Wiring (Splice Required for Slave Actuator) The exte

Strany 5 - GENERAL REQUIREMENTS

11STEP 6 Installation of Charging Source SOLAR PANEL Locate and mount the solar panel bracket so that the panel faces southwest and mai

Strany 6 - MOUNTING SITE REVIEW

12STEP 9 Making Final Adjustments In order to make final adjustments, a signal device such as a radio control should be used. The control board

Strany 7 - PARTS INCLUDED

13LIMIT SWITCHES The limit switch adjustments are located on the bottom of the actuator. Remove the dust plug to make adjustments. Th

Strany 8

14Circuit Board Terminal Description For Accessories Patriot Control Board TERMINAL DESCRIPTION 1 + 12 volt dc Output. *M

Strany 9 - IMPORTANT:

15DS1 Programming Switches Factory settings are shown in bold italic type 1 Automatic Close Timer Enable ON Timer to clos

Strany 10

16DS2 Programming Switches Factory settings are shown in bold italic type 1 Solenoid lock enable / Gate in operation indicator ON

Strany 11 -

17SAFETY SECTION USAutomatic gate operators are certified to UL325 Vehicular Class I and Class II swing gate standards. UL325 identifies f

Strany 13 - Red wire + Black wire

18WARNING: TO REDUCE THE RISK OF INJURY OR DEATH 1. READ AND FOLLOW ALL INSTRUCTIONS 2. Never let children operate or play with gate controls. Ke

Strany 14 - IMPORTANT NOTES

19SAFETY SECTION Remedies for Safety Concerns Zone 1 Safety edges and photo electric eyes are the most common types of pro

Strany 15 - LIMIT SWITCHES

20SAFETY SECTION Remedies for Safety Concerns Zone 3 Safety edges are the best protection. A photo eye may also be used. For vehi

Strany 16 - TERMINAL DESCRIPTION

21Periodic Service All gate operators require periodic checking and adjustments by a qualified technician of the control mechanism for force (load),

Strany 17 - DS1 Programming Switches

22TROUBLESHOOTING SECTION OUTLINE 1 Single gate will not operate. 2 Dual gate will not operate. 3 Single or Dual gate opens or closes very slow.

Strany 18 - Emergency Manual Release

231. My single gate will not operate Patriot I: STEP 1 Remove control box cover locate the “Open/Close Command” push button and press it to operat

Strany 19 - SECONDARY ENTRAPMENT DEVICES

24NOTE: The USAutomatic multi stage charger does not output any voltage or current when disconnected from the battery, you cannot check charger by d

Strany 20

25 7. Dual Gate opens or closes correctly then immediately reverses direction: STEP 1 This is most likely caused by an incorrect limit switch adju

Strany 21

2610 Photo-eye, safety loop or other safety accessory will not reverse the gate when closing or hold the gate open STEP 1 The first thing to chec

Strany 22

27ACCESSORY WIRING DIAGRAMS NOTE: Ensure that battery power is disconnected from the control board before wiring accessories to the control board.

Strany 23 - Troubleshooting Guide

1INTRODUCTION This operator is intended to be installed on vehicular Class I or Class II gates as defined by UL 325. Maximum gate load not to excee

Strany 24 - Terms and Definitions

28Radio Receiver Multi-Code 1099-40 or Digi-Code 5100 Radio Receiver Allister 9931-LV 3 wire with F Connector Radio Re

Strany 25

291 2 3 4 5 6 7 8 9 10 11 12Keypad (12 Volt D.C.) (Momentary Contact Signal) Keypad Card Reader or Telephone Access Unit Wiring

Strany 26

301 2 3 4 5 6 7 8 9 10 11 12Safety Edge Wiring (Wireless Type) Secondary Entrapment Device (Safety Edge Transmitter & Radio Receiver) 

Strany 27

31Siren Secondary Entrapment / Indicating Light For Gate Position Light illuminates anytime gate is not closed (4 second delay)

Strany 28

32Loops Loop Position Diagram Single Swing Gate with 2 Loops Dual Swing Gate with 2 Loops

Strany 29 - ACCESSORY WIRING DIAGRAMS

33Loops Typical Loop Saw cut Proper wiring of two loops performing the same function. Example: Inside and Outsid

Strany 30

34Loops Loop Size Chart The loop size is based on the width of the driveway. If the driveway is 14' wide, the loop would be a 6'x6'

Strany 31 - Keypad (12 Volt D.C.)

PATRIOT I PATRIOT II Limited 5 Year Warranty The PATRIOT Gate Operator is warranted to be free of defects in materials or workmanship for a pe

Strany 32

2Table Of Contents Page Introduction... 1 Table of Contents...

Strany 33 - USAutomatic MADE IN USA

3GENERAL REQUIREMENTS General hand/tools such as combination wrenches, tape measure, level, clamps, etc. are required. Your particular installation

Strany 34 - Center Loop

4IMPORTANCE OF A PROPERLY DESIGNED GATE As a general rule a gate, which is to be automatically operated must be stronger and smoother than one, w

Strany 35 - Loops

515 PARTS INCLUDED Cabinet with Control Board and Receiver OR

Strany 36

6STEP 1 Hinge Mount Tube Installation (Part 1) PULL TO OPEN / TOP VIEW (SEE BOTTOM OF PAGE FOR PUSH TO OPEN) (Left-handed installation show

Strany 37 - USAutomatic

7STEP 1 Hinge Mount Tube Installation (Part 3) VERTICAL HEIGHT POSITIONING Refer to figures 2B-2F to determine the best location for the actu